Skip to content

ECADD panic (Point1 is not on the curve) #9020

Open

Description

@sirasistant

Reproduced here #9019
Relevant code:
https://github.com/AztecProtocol/aztec-packages/blob/master/noir-projects/noir-contracts/contracts/avm_test_contract/src/main.nr#L149
https://github.com/AztecProtocol/aztec-packages/blob/master/noir/noir-repo/noir_stdlib/src/embedded_curve_ops.nr#L29
https://github.com/AztecProtocol/aztec-packages/blob/master/noir/noir-repo/noir_stdlib/src/embedded_curve_ops.nr#L139

resulting point1_1

    {
      p1X: Field {
        rep: Fr<0x0000000000000000000000000000000000000000000000000000000000000002>
      },
      p1Y: Field {
        rep: Fr<0x0000000000000002cf135e7506a45d632d270d45f1181294833fc48d823f272c>
      },
      p1IsInfinite: true
    }

This makes sense since if the two points are equal, noir is adding 1 to the x, using the same y and setting infinite to true.
The AVM panics trying to perform an ecadd with this point1.

Activity

  1. added
    C-avmComponent: AVM related tickets (aka public VM)
    on Oct 4, 2024
  2. added a commit that references this issue on Oct 8, 2024
    fc95fa1