Async2CollectibleAlc.TestEntryPoint fails on browser-Wasm CoreCLR because the host does not expose a usable assembly path for loading a second copy into a collectible AssemblyLoadContext.
The failure reproduces in both interpreter and ReadyToRun execution.
Expected behavior
The test should locate a loadable copy of collectible-alc.dll, load it into a collectible AssemblyLoadContext, execute the runtime-async method, unload the context, and pass.
Actual behavior
Assembly.GetExecutingAssembly().Location is empty in the browser host, and AssemblyLoadContext.LoadFromAssemblyPath fails before the runtime-async assertions execute:
System.ArgumentException: Path "" is not an absolute path. (Parameter 'assemblyPath')
at System.Runtime.Loader.AssemblyLoadContext.LoadFromAssemblyPath(String assemblyPath)
at Async2CollectibleAlc.CallFooAsyncInCollectibleALC(Task task)
Regression?
Unknown. This was exposed while enabling the full src/tests/async runner for browser CoreCLR.
Known Workarounds
Skip only Async2CollectibleAlc.TestEntryPoint when PlatformDetection.IsWasm is true. Preserve native-platform coverage.
Configuration
Browser CoreCLR
WebAssembly
Checked runtime, Release libraries
Interpreter and ReadyToRun execution under Node
Other information
A complete fix needs a browser-host-supported mechanism for supplying the test assembly bytes or a loadable path to the collectible ALC.
Note
This issue was generated with GitHub Copilot assistance.
Description
Async2CollectibleAlc.TestEntryPointfails on browser-Wasm CoreCLR because the host does not expose a usable assembly path for loading a second copy into a collectibleAssemblyLoadContext.Reproduction Steps
Build browser-Wasm CoreCLR and run:
The failure reproduces in both interpreter and ReadyToRun execution.
Expected behavior
The test should locate a loadable copy of
collectible-alc.dll, load it into a collectibleAssemblyLoadContext, execute the runtime-async method, unload the context, and pass.Actual behavior
Assembly.GetExecutingAssembly().Locationis empty in the browser host, andAssemblyLoadContext.LoadFromAssemblyPathfails before the runtime-async assertions execute:Regression?
Unknown. This was exposed while enabling the full
src/tests/asyncrunner for browser CoreCLR.Known Workarounds
Skip only
Async2CollectibleAlc.TestEntryPointwhenPlatformDetection.IsWasmis true. Preserve native-platform coverage.Configuration
Other information
A complete fix needs a browser-host-supported mechanism for supplying the test assembly bytes or a loadable path to the collectible ALC.
Note
This issue was generated with GitHub Copilot assistance.